This website uses its own operating cookies that will be installed. We also use third-party cookies:
- Google Analytics: used to collect statistical information about our website and perform marketing with Adwords.
- Zendesk: necessary for the operation of the online assistance chat.
As long as you don't accept, the third-party cookies will not be installed. More information.
Our PRPAC cable gland with a nickel-plated brass body enables fast installation thanks to an innovative push-fit fixing system, eliminating the need for locknuts or threaded holes. It is especially suitable for installations in confined spaces or where rear access is limited.
The spring fixing mechanism allows the cable gland to be inserted from the outside and locked with light pressure and a clockwise turn, ensuring secure fastening even under vibration. The spring adapts to panel thicknesses from 0.5 to 4 mm. Installation is carried out exclusively from the outside, reducing assembly time and increasing production efficiency by up to 75%. Manufactured according to DIN EN 62444/50262, it offers high pull-out resistance, IP protection and UV resistance. Available for mounting diameters from 16 to 40 mm. Removal must be carried out using the special MHPRP tool, supplied in the packaging and also available separately.
· Material: nickel-plated brass body, lamellar sleeve and PA6 lower insert, chloroprene seal and flat O-ring
· Operating temperature: -20 °C / +100 °C (peaks from -40 °C / +150 °C)
· Protection: IP66 / IP68 (up to 5 bar), Type 1 / 4X (UL50E), UL94-V2, CE
On request, multi-hole inner seals are available as replacements for the standard seals, as well as versions in stainless steel 303 and 316L. Please contact our sales department.
For the temporary closure of cable glands, the DTPB plug can be used to provide protection against dust and water splashes during assembly, transport or when not in use.